Cooling channel form test unit FPG 1000 – According to the construction heatable, electronic acquisition protocol incl. serial interface Com 1.
- Cleaning and rinsing of the cooling channels
- Control of the flow rate
- Density control of the cooling channels and the interfaces
- Dry rinsing with compressed air
- Bypass function incl. changeover for forward and runback with ball valves
-
Workpiece material
- Metal
- Plastics
-
Sizes
- Modular systems
-
Cleaning
-
Methods
- Solutions for high pressure cleaning
- Rinsing | Oscillation | Immersion cleaning
-
Specifications
Channels:
1Pressure test:
7 barCleaning pressure medium:
2–4 barNecessary compressed air connection:
6 barVolume flow / Pump:
18 l/minPower connection V/A / Hz:
400/16 / 50Tank capacity min./max.:
30 lFilter element min./max.:
100/300 μDimensions (LxBxH):
800x800x1120mmWeight:
180 kg